PFM923I-6UN-C

৳ 16,200.00

305m UTP CAT6 LSZH CPR E Cable

> 305 m (1000 ft)/carton UTP CAT6, power over Ethernet, compatible with one cable

> High-purity oxygen-free copper conductor

> Customized PVC outer sheath; CE CPR Eca flame retardant class certified

> 01-year warranty

Category:

Description

Dahua PFM923I-6UN-C 305m UTP CAT6 LSZH CPR E Cable is compatible with power over Ethernet and comes in a 305m (1000 ft) carton. It features a high-purity oxygen-free copper conductor and a customized PVC outer sheath. The cable is CE CPR Eca flame retardant class certified.

Dahua PFM923I-6UN-C Specification

Conductor

Material

Oxygen free copper (99.97% purity)

Diameter

0.53mm ± 0.01 mm

Insulation

Material

HDPE

Min. Average Thickness

0.21 mm

Diameter

0.95 mm ± 0.1 mm

Color (4 Pairs)

Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

Separator

Material

PE

Specification

Translucent 4.5 × 0.4 mm

Rip Cord

Material

Polyester

Specification

500D

Sheath

Material

LSZH

Min. Average Thickness

0.5 mm

Diameter

6.0 mm ± 0.3 mm

Color

White

Electrical

Max. DC Resistance of a Single Conductor

8.7 Ω/100 m

Min. Insulation Resistance

5000MΩ·km

Max. DC Resistance Unbalance

2% (pair intra), 4% (pairs inter)

Dielectric Strength

No breakdown with 1KV DC for 1 min

Transmission

Characteristic Impedance

100 ± 15Ω

Near End Cross Talk

≥39.30 dB/100 m@250 MHz

Max. Attenuation

34.8 dB/100 m@250 MHz

Return Loss

≥17.3 dB/100 m@250 MHz

Mechanical

Tensile Strength

Sheath≥10 MPa, insulation≥16 MPa

Elongation at Break

Sheath≥125%, insulation≥300%

Installation Bending Radius

>8 times of outer cable diameter

Conductor Elongation at Break

≥10%

Environmental

Shrinkage of Insulation

≤5%

Color Migration Resistance of Insulation

No migration

Sheath Tensile Strength and Elongation at Break after Aging

≥8 MPa, ≥100%

Low Temperature Bending Test

No cracking after the test

Heat Shock Test

No cracking after the test

Operation Temperature

–20°C to +60°C (–4°F to 140°F)

Installation Temperature

0°C to +50°C (32°F to 122°F)

Storage Temperature and Humidity

–10°C to +40°C (14°F to 104°F), <60% (RH)

Security

Vertical Fire Propagation Test

Comply with IEC 60332-1-2

Packaging

Cable Length

305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)

Inner Carton Dimensions

416.0 mm × 412.0 mm × 220.0 mm (16.38″ × 16.22″ × 8.66″) (L × W × H)

Packaging Method

305.0 m (1000.66 ft) a carton, one carton with 2 inner cartons

Net Weight

≥10.5 kg (23.15 lb)

Gross Weight

≥11.5 kg (25.35 lb)

Compliance

Executive Standards

Q/DXJ 067-2019, EN50575-2014

Certification

Certification

CPR Eca